In the rare event that the Naked System senses an over voltage such as a power surge or spike particularly during a storm or after a loss of power, it may revert to a 'Factory Setting' mode that requires a manual reset to restart the system.
The screen will appear like this:
Please follow the below instructions to reset your Naked System.
1. Switch the unit off at the wall
2. Hold the [+] button and turn back on at the wall.
You will see 'Factory Settings' displayed on the screen.
3. Release the (+) button and press [OK]
4. Press [+] to scroll to F18,F19 or F20 (depending on the model) EXIT FACTORY SET
5. Press [OK]
6. Press [POWER]CustomerStart
The unit will now reboot and you can begin entering the details for your pool.
When asked if Copper is present in the pool please select [+] YES and if you have a NKD-pH Controller be sure to press [+] YES.
The unit will switch to AUTO and resume normal operation, you can now make adjustments to the TIMER settings that you may have adjusted previously.
Information on TIMERS can be found in the following article https://support.naked-pools.com/hc/en-au/articles/5320008060431-Adjusting-the-Clock-and-Timers.
Should you need any further assistance please CONTACT US.